9 heading data – Furuno MARINE RADAR 1823C User Manual

Page 54

Advertising
background image

3-10

3.3.8 STC

CURVE

The default STC curve can be maintained in most cases. If necessary the STC curve can
be changed as follows:

1. Open the RADAR SETUP menu and select STC CURVE.
2. Press the EDIT soft key or [ENTER] knob to show the setting window.

RETURN

NARROW
NORMAL
WIDE

STC CURVE

STC curve setting window


3. Select STC curve;

NARROW:

The effective range of the [A/C SEA] adjustment is relatively short.

NORMAL:

Between NARROW and WIDE.

WIDE:

The effective range of the [A/C SEA] adjustment is relatively long.

4. Press the RETURN soft key to finish.

3.3.9 HEADING

DATA

Select the heading reference, MAGNETIC or TRUE. Select MAGNETIC when connecting
with the magnetic compass, select TRUE when connecting with the true compass. For your
reference, when connecting with Satellite Compass SC-60/120 or Integrated Hading Sensor
PG-1000 which Furuno makes, set the heading data as the table shown below.

Model

Setting of HEADING DATA

with L/L data

TRUE

PG-1000

w/o L/L data

MAGNETIC

SC-60/120 TRUE


1. Open the RADAR SETUP menu and then select HEADING DATA.
2. Press the EDIT soft key or [ENTER] knob to show the setting window.

HEADING DATA

MAGNETIC
TRUE

Heading data setting window

3. Select MAGNETIC or TRUE.
4. Press the [ENTER] knob or ENTER soft key.

Advertising