For connection with the CCD camera/video recorder, the following cable is necessary
(local supply).

Both side connectors: RCA connector (metal)

Cable length: shorter than 10 m

2.5C2V or 3C2V (Japan Industrial Standard (JIS), or the equivalent) coaxial cable
(Impedance: 75

)

Conductor
S = 0.19 mm

= 0.5 mm

2

Vinyl

sheath

Shield

Cable 3C2V

Insulator

3C-2V cable, sectional view

1. Remove the display unit cover, POWER Board and power shield case referring to the

step 1 through 4 on the “4.1 ARP kit ARP-11.”

2. Attach the NTSC/PAL Interface Board to the SPU Board with four pan head screws

(M3x6, supplied with optional kit) so that J700 connector on the NTSC/PAL Interface
Board faces to J107 on the SPU Board.

3. Attach the connector assy RCA-TMP-L230 to J701 on the NTSC/PAL Interface Board.

NTSC/PAL Interface Board

Pan head screws
(M3x6, supplied with optional kit) 4pcs.

J700

J107

Connector assy RCA-TMP-L230