Operating the Fryer

A. Turn the computer on by pressing the

switch.

1. One of the following displays will appear:

a.

, indicating that the element is operating in the melt-cycle mode. Fryer will

remain in the melt-cycle mode until it reaches 180

°F (82°C) or is canceled manually.

b.

, indicating that the pot temperature is 21

°F (12°C) or higher than the setpoint.

c.

, indicating that the pot temperature is 21

°F (12°C) or lower than the setpoint.

d. "

" indicating that the fryer temperature is in the cooking range. NOTE: For best

results, do not cook product until the display reads "

".

e.

, indicates a heating problem.

f.

, indicates that the pot temperature is more than 410

°F (210°C) [395°F (202°C) for

CE (European Community) fryers].

g.

, indicates that the computer has detected a problem in the temperature measuring

circuits, including probe.


NOTE: "." decimal point between digits 1 and 2 in either display area indicates that the heating

element is on.


B. Melt-Cycle Cancel Feature (built-in computers only).

CAUTION

Do not cancel the melt cycle mode if using solid shortening.


The computer will display

during melt-cycle operation. To cancel melt cycle on a full pot,

depress the "R" button

. To cancel the melt cycle on a split pot, use "L" button

for left side

pot and "R" button

for right side.

will be replaced by

. The decimal point between

digits 1 and 2 will illuminate indicating that the elements are on.


C. Cook-cycle operation is initiated by pressing the product switch:

1. The basket lift (on fryers so equipped) will lower the product into the cooking oil/

shortening.