5.3 Host Commands

C141-E239

5-67

Table 5.19 Data format of SMART Summary Error Log (2/2)

Byte Item

5C to 1C3

Error log data structure 2

to

Error log data structure 5

1C4, 1C5

Total number of drive errors

1C6 to 1FE Reserved

1FF Check

sum

•

Command data structure

Indicates the command received when an error occurs.

•

Error data structure

Indicates the status register when an error occurs.

•

Total number of drive errors

Indicates total number of errors registered in the error log.

•

Checksum

Two's complement of the lower byte, obtained by adding 511-byte data one byte at a
time from the beginning.

•

Status

Bits 0 to 3: Indicates the drive status when received error commands according

to the following table.

Bits 4 to 7: Vendor unique

Status Meaning

0 Unclear

status

1 Sleep

status

2 Standby

status

3

Active status (BSY bit = 0)

4

Off-line data collection being executed

5 to F

Reserved