(5) Current Requirements and Power Dissipation

Table 1.3 lists the current and power dissipation (typical).

Table 1.3 Current and power dissipation

Typical RMS Current

Typical Power (*3)

Spin up (*1)

900 mA

4.5 W

Idle (*6)

100 mA

0.5 W

R/W (on track) (*2)

320 mA

1.6 W

Seek (*5)

380 mA

1.9 W

Standby (*6)

26 mA

0.13 W

Sleep (*6)

26 mA

0.13 W

Energy
Efficiency (*4)

0.003 W/GB (rank E / MHV2160BT)

*1

Maximum current and power at starting spindle motor.

*2

Current and power level when the operation (command) that accompanies a
transfer of 63 sectors is executed 3 times in 100 ms

*3

Power requirements reflect typical values for +5 V power.

*4

Energy efficiency based on the Law concerning the Rational Use of Energy
indicates the value obtained by dividing power consumption by the storage
capacity. (Japan only)

*5

The seek average current is specified based on three operations per 100
msec.

*6 IPM mode: Slumber mode.