3 checking burner manifold gas pressure – Frymaster FMCFEC User Manual

Page 10

Advertising
background image

MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-5

1.3 Checking Burner Manifold Gas Pressure

WARNING

This task should be performed by qualified service personnel only.


1. Ensure that the gas valve knob or button is in the OFF position.

2. Remove the pressure tap plug from the end of the manifold (see illustration below) and connect a

gas pressure-measuring device to the port.

Remove plug to connect a gas

pressure-measuring device to the port.


3. Place the gas valve in the ON position then place the fryer power switch in the ON position

(where applicable). When the burner lights and continues to burn, compare the pressure reading
to that for the corresponding gas in the tables below and on the next page.

Model

Gas Type

G20

G25

G31

Pressure

(mbar)

1

20

20-25

37-50

Number

of

Orifices

21

21

21

Manifold

Pressure

7,5

10

14,9

CE Standards for Incoming Gas

Pressures

MJCF/J65 CE

Orifice

Size

1,40

1,40

0,95

1

(mbar) = 10,2 mm CE

Air Flow

(m

3

/H)

3,62

4,18

2,35