MASTER JET CF SERIES ATMOSPHERIC GAS FRYERS

CHAPTER 1: SERVICE PROCEDURES

1-6

1.3 Checking Burner Manifold Gas Pressure (cont.)

Non-CE Standard

for Incoming Gas Pressures

Gas

Minimum

Maximum

Natural

6" W.C.

1.49 kPa

14.93 mbar

14" W.C.
3.48 kPa

34.84 mbar

LP

11" W.C.
2.74 kPa

27.37 mbar

14" W.C.
3.48 kPa

34.84 mbar

Gas

Natural

LP

8.25" W.C.

2.0 kPa

20.0 mbar

Pressure

Non-CE Standard

3.5" W.C.

.75 kPa

7.5 mbar

for Burner Manifold Gas Pressures


4. If the measured manifold gas pressure does not match the appropriate pressure in the preceding

tables, remove the cap from the gas valve regulator and adjust to the correct pressure.

Honeywell Valve

(Non-CE Units)

Honeywell Valve

(CE Units)

Regulator Adjustment Screw Cap


1.4 Adjusting Pilot Flame


1. On non-CE valves, remove the cap covering the pilot adjustment screw. On all valves, turn the

pilot adjustment screw counterclockwise to increase the length of the flame or clockwise to
decrease the length of the flame. Adjust the flame to a length of 1 to 1-½ inches (25 to 38 mm).

Honeywell Valve

(Non-CE Units)

Honeywell Valve

(CE Units)

Pilot Adjustment Screw

On Non-CE gas valves, remove this cap to
access Pilot Adjustment Screw.

2. On Non-CE valves, reinstall the pilot adjustment screw cap.