P13 Change

Temp

The percentage of a temperature based chill cycle, which is passed before automatically adjusting the air
temperature set point to 1°C.The range is adjustable in 5% increments.

Range 5% to 95%.

Hard Max
P14 Air

Temp

The temperature, which the air probe must read before the condensing system is de-energised in the chill mode
of the Hard Chill Max Program.
Range -20°C to 15°C.

P15 Chill

Time

The period Hard Chill Max program is in chill mode prior to entering Hold mode in a time based chill cycle.
Range 5 minutes to 480 minutes.

P16 Chill

Temp

The temperature, which the Food Probe 1 must read before the condensing system is de-energised in the chill
mode of the Hard Chill Max program prior to entering the Hold mode of a temperature based cycle.
Range -15°C to 15°C.

P17 Hold

Temp

The temperature, which the air probe must read before the condensing system is de-energised in the Hold mode
of the Hard Chill Max program.

Range -15°C to 15°C.

Shock Freeze
P18 Air

Temp

The temperature, which the air probe must read before the condensing system is de-energised in the chill mode
of the Shock Freeze Program.
Range -35°C to 15°C.

P19 Chill

Time

The period Shock Freeze program is in chill mode prior to entering Hold mode in a time based chill cycle.
Range 5 minutes to 480 minutes.

P20 Chill

Temp

The temperature, which the Food Probe 1 must read before the condensing system is de-energised in the chill
mode of the Shock Freeze program prior to entering the Hold mode of a temperature based cycle.
Range -15°C to 15°C.

P21 Hold

Temp

The temperature, which the air probe must read before the condensing system is de-energised in the Hold mode
of the Shock Freeze program.

Range -35°C to 15°C.

Professional 1
P22

Air Temp Std
The standard temperature, which the air probe must read before the condensing system is de-energised in the
chill mode of the Professional 1 Program.
Range -20°C to 15°C.

P23

Chill Time Std
The standard period Professional 1 program is in chill mode prior to entering Hold mode in a time based chill
cycle.
Range 5 minutes to 480 minutes.

P24

Chill Time Minimum

The minimum period Professional 1 program is in chill mode prior to entering Hold mode in a time based chill
cycle that it can be adjusted to by the operator.

Range 5 minute to 60 minutes.

P25

Chill Time Maximum

The maximum period Professional 1 program is in chill mode prior to entering Hold mode in a time based chill
cycle that it can be adjusted to by the operator.

Range 60 minute to 480 minutes.

P26

Chill Temp Std
The standard temperature, which the Food Probe 1 must read before the condensing system is de-energised in
the chill mode of the Professional 1 program prior to entering the Hold mode of a temperature based cycle.
Range -15°C to 15°C.