Frymaster FOOTPRINT RE80 User Manual

Page 19

Advertising
background image

1-14

1.11 Interface Board Diagnostic Chart

The following diagram and charts provide ten quick system checks that can be performed using only
a multimeter.


















Meter Setting

Test

Pin

Pin

Results

12 VAC Power

50 VAC Scale

3 of J2

1 of J2

12-16 VAC

24 VAC Power

50 VAC Scale

2 of J2

Chassis 24-30 VAC

*Probe Resistance (RH)

R X 1000 OHMS

11 of J2

10 of J2 See Chart

*Probe Resistance (LH)

R X 1000 OHMS

1 of J1

2 of J1

See Chart

High-Limit Continuity (RH)

R X 1 OHMS

9 of J2

6 of J2

0 - OHMS

High-Limit Continuity (LH)

R X 1 OHMS

6 of J1

9 of J1

0 - OHMS

Latch Contactor Coil (RH)

R X 1 OHMS

8 of J2

Chassis 3-10 OHMS

Latch Contactor Coil (LH)

R X 1 OHMS

5 of J1

Chassis 3-10 OHMS

Heat Contactor Coil (RH)

R X 1 OHMS

7 of J2

Chassis 11-15 OHMS

Heat Contactor Coil (LH)

R X 1 OHMS

4 of J1

Chassis 11-15 OHMS

* Disconnect 15-Pin harness from the computer/controller before testing the probe circuit.

Diagnostic LED Legend

CMP indicates power from 12V transformer
24

indicates power from 24V transformer

HI

(RH) indicates output (closed) from right latch
relay

HI

(LH) indicates output (closed) from left latch relay

HT

(RH) indicates output from right heat relay

HT

(LH) indicates output from left heat relay

AL

(RH) indicates output (open) from right latch relay

AL

(LH) indicates output (open) from left latch relay

NOTE –

When testing the test points on J1

and J2 test use the illustration above dis-
regarding any silk-screened numbers on
the board depicting the location of Pin 1.
Pin 1 is located in the bottom right corner of
both J1 and J2. These test points are ONLY
for RE Series boards with J1 and J2 plugs on
the front of the board.

PN 106-6664

Advertising