ELECTRICAL POWER SPECIFICATIONS

Three (3) Phase Requirements

kW VOLTAGE

PHASE

WIRE

SERVICE

MINIMUM SIZE

AMPS PER LEG

AWG mm2 L1 L2

L3

17 208

3

3

6

16

48

48

48

17 240

3

3

6

16

41

41

41

17 480

3

3

6

16

21

21

21

17 220/380

3 4 6

16

26

26

26

17 240/415

3 4 6

16

24

24

24

17 230/400

3 4 6

16

25

25

25

21 208

3

3

4

25

57

57

57

21 240

3

3

4

25

50

50

50

21 480

3

3

6

16

25

25

25

21 220/380

3 4 6

16

N/A

N/A

N/A

21 240/415

3 4 6

16

29

29

29

21 230/400

3 4 6

16

27

27

27