background image

Replace filter O-rings

Quarterly

FR 3 Q4

©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2009

Page 1 of 1

Frymaster Fryer Model BIELA14 and BI

GLA30 – LOV

Quart

erly

FR 3 Q4

Why

To keep the fryer’s filter pump in working order

Time required

2 minutes to prepare

5 minutes to complete

Time of day

At open; the fryer must be cool

For 24-hour restaurants: During a low-volume period
when the fryer can be turned off

Hazard icons

Tools and supplies

O-rings for the filter

pump

Flat tip screwdriver

No-scratch pad

Procedure

1

Prepare fryer for procedure.
Check to make sure the fryer
is cool. This procedure should
be done only when the fryer is
cool and the filter pan is
empty.

2

Remove filter pan.
Pull the filter pan out of the
cabinet.

3

Replace O-ring.
Remove the O-ring from the
pan nozzle. Replace the O-
ring with a new O-ring. O-
rings can be purchased from
your local authorized servicer.

Use only the manufacturer’s
replacement O-ring. These
rings are manufactured spe-
cifically for use with hot
cooking oils. Generic O-rings
cannot be used for this pur-
pose.

4

Clean pickup tubes.
Clean the male and female
pickup tubes with a no-
scratch pad.

5

Reinstall filter pan.
Reinstall the pan into the
fryer cabinet.

Advertising