SK-96370-144PMC-GDC User Guide

Chapter 3 Jumpers and Switches

FMEMCU-UG-960014-10

- 18 -

© Fujitsu Microelectronics Europe GmbH

3.6 Reset

Generation

(JP: 33, 41, 46, 47, 48)

In addition to the internal Power-On reset, the microcontroller can be reset by an external
reset circuit (Voltage Monitor) and also by a RS232 interface. Refer to the chapter ‘LIN /
UART Connectors (X5 or X9)’ for DTR / RTS selection.

JP33 Selects X5 or X9 as reset source.

JP41

The signal on the DTR/RTS line can be negated with this jumper.

Remove the jumper in order to disable the RS232 reset circuit.

JP46

Selects the mode of the reset button SW6.

JP47

A voltage supply monitor allows monitoring of 1V8 or 2V5 power supply.

JP48

Open this jumper if no external Reset shall be generated.

In this case only the internal reset is active (e.g.: power-on).

Jumper

Setting

Description

1-2

X5 (UART0) is used to generate Reset

JP33

(UART RESET)

2-3

X9 (UART2) is used to generate Reset

1-2

No polarity inversion for the DTR/RTS signal

JP41

(DTR / DTRx)

2-3

Polarity inversion for the DTR/RTS signal

1-2

Reset is applied immediately when SW6 is pressed

JP46

(Reset imm./delayed)

2-3

Reset is applied when SW6 is pressed > 2sec

1-2

The voltage supply monitor observes 1V8

JP47

(Monitor 1V8 / 2V5)

2-3

The voltage supply monitor observes 2V5

Closed

External reset generation is active

JP48

(RST MCU)

Open No

external

reset

generation

Table 3-5: Reset Connection

By default, the external reset is enabled and set to immediate reset while the reset by UART
is disabled.


Note:

While a reset signal is asserted the red Reset-LED LD13 is lit.

During normal operation, this LED should be off!

If JP41 (DTR/DTRx) is set, the UART RESET jumper (JP33) and the according DTR/RTS
(JP23 and JP38) jumper have to be set, too.

If the reset LED is steadily on, check the power supply input voltage and the settings for the
reset-generation by UART.