FUJITSU MB96300 User Manual

Page 20

Advertising
background image

SK-96370-144PMC-GDC User Guide

Chapter 3 Jumpers and Switches

FMEMCU-UG-960014-10

- 20 -

© Fujitsu Microelectronics Europe GmbH

3.9 LIN / UART

There are two identical circuit blocks for LIN or RS232 connections. Each of the two D-Sub
connectors can be configured as LIN or RS232 interface. DTS or RTS can be selected as
reset source, and RTS and CTS can be connected by a jumper, since some terminals and
Flash programming tools need this connection. Pin 1 (Vs) of X5 and X9 can be connected to
the voltage input of the board by jumpers in order to supply the LIN bus.

3.9.1 LIN-UART 0 (JP: 19, 21, 23, 25, 27, 28, 29, 31)

Jumper

Setting

Description

1-2

SIN0 is connected to RS232 transceiver

JP21

(RXD)

2-3

SIN0 is connected to LIN transceiver

1-2

SOT0 is connected to RS232 transceiver

JP25

(TXD)

2-3

SOT0 is connected to LIN transceiver

1-2

X5 pin 2 is connected to RS232 transceiver

JP27

(RS232/LIN)

2-3

X5 pin 2 is connected to LIN transceiver

Closed

RTS and CTS of X5 are connected

JP19

(RTS-CTS)

Open

RTS and CTS of X5 are not connected

1-2

DTR signal (pin 6 of X5) is used as reset source

JP23

(DTR/RTS)

2-3

RTS signal (pin 7 of X5) is used as reset source

Closed

LIN transceiver is enabled

JP29

(LIN enable)

Open

LIN transceiver is disabled

Closed

LIN-UART0 is LIN Master

JP31

(LIN master)

Open

LIN-UART0 is LIN Slave

Closed

LIN bus (X5 pin 1) is powered by the board

JP28

(LIN Vbat)

Open

LIN bus (X5 pin 1) is not powered by the board

Table 3-7: UART0 Settings

Advertising