SK-96370-144PMC-GDC User Guide

Chapter 3 Jumpers and Switches

© Fujitsu Microelectronics Europe GmbH

- 23 -

FMEMCU-UG-960014-10

3.13 Graphic Display Controller interface (JP: 54, 55, 56, 57, 58, 60, 85, 86)

The SK-96370-144PMC-GDC provides the external bus interface on the two connectors
X10 and X11 in order to support Graphic Display Controller sub-boards,

e.g.: CREMSON-STARTERKITLIME.

Take care of proper jumper settings, in case those external sub-boards will be connected.
Some signals, like A22, CS2 and CS3, are shared with the on-board FLASH and SRAM
memory (see also chapter 3.11 and 3.12).

JP54

Address line A24 is not supported by the microcontroller

JP55

Address line A25 is not supported by the microcontroller

JP56

Signal sharing of A22 and CS2 for FLASH and GDC

JP57

Chip selection for external sub board

JP58

1.8V power supply

JP60

Mains power supply

JP70, 71 The port P08_0 may be used e.g. to generate manual reset on the sub board.

Jumper

Setting

Description

Open

Address line A24 is floating

JP54

(A24)

Closed

Address line A24 is connected to GND

Open

Address line A25 is floating

JP55

(A25)

Closed

Address line A25 is connected to GND

2-4

Address line A22 is connected to the FLASH

JP56

(GDC/FLASH)

1-2
3-4

CS2 is connected to the connector (see jumper JP57), too
Address A22 of FLASH is connected to GND

1-2

Connect CS3 to the connector

JP57

(CS2/CS3)

2-3

Connect CS2 to the connector

Open

1.8V is not supplied to connector X11B

JP58

(1V8)

Closed

1.8V is supplied to connector X11B

Open

Mains is not connected to connector X11B

JP60

(Mains)

Closed

Mains is connected to X11B

Open

P08_0 is not connected to X11A_11A

JP70

(GLRST)

Closed

P08_0 is connected to X11A_11A

Open

P08_0 is not connected to X11A_12A

JP71

(FLRST)

Closed

P08_0 is connected to X11A_12A

Table 3-12: Graphic Display Controller interface