KSCF18G COOL ZONE SERIES GAS FRYERS

CHAPTER 4: DAILY OPERATION

4-1

4.1 General Use

1. At opening, always check that the power switch and the computer are OFF.

2. For consistent quality product, convenience, and long-term savings, use a high-quality liquid

shortening.

3. If using solid shortening, never melt a block of shortening by placing an entire block in the

fryer vessel. Cut it into small pieces and pack it around fryer components.

4. Although 350°F (177°C) is the recommended temperature for most cooking operations, set

the fryer at the lowest possible temperature which produces a high quality end product while
ensuring maximum life for your oil.


4.2 Start-Up Procedures

1. If the fryer is empty, pour enough oil into the frypot to fill it to the bottom OIL LEVEL line

scribed on the rear wall. If solid shortening is used, melt the shortening following
procedures in Section 3.11, Final Preparation.


2. A. Pilot lighting procedures – Standing Pilot:

a. Turn off the manual shut-off valve on the incoming service line.

b. Turn the operating thermostat to OFF.

c. Depress the Pilot Off button (red) on the combination safety gas valve to turn it off.

d. Wait at least five minutes for any accumulated gas to disperse.

e. Open the manual shut-off valve on the incoming service line.

f. Press and hold the white pilot light button and repeatedly press the piezo ignitor

button until the pilot lights. Release the white button after approximately 45-60
seconds.