Frymaster GEN II LOVTM BIELA14 User Manual

Page 62

Advertising
background image

5-6

5.4.4 Filter Error Flowchart

This chart follows the process of clearing
a filtration issue. The prompt is
displayed when any of the following
occur:

1. a clogged filter pad,
2. a tripped or defective filter pump,
3. a leaky O-ring on the pick-up tube,
4. a failed drain valve/actuator, or
5. a failed return valve/actuator.

If the computer displays

SERVICE

REQUIRED, the fryer can be used in
most cases by answering

NO when the

prompt for

SYSTEM ERROR

FIXED? YES NO is displayed. The
message repeats every 15 minutes until
the issue is repaired and fryer reset by a
technician.

Advertising