3 noise rejection – Furuno FAX-30 User Manual

Page 36

Advertising
background image

2. FAX OPERATION: NAVNET

2-14

2.5.2

Phasing signal out of synchronization

The SYNC soft key functions to fine tune the phasing signal. If the dead sector is
plotted at an angle even when the phase is properly selected, adjust the
synchronization to display the dead sector straightly.

Example of phasing signal out of synchronization

1. With a facsimile image displayed (see paragraph 2.4), press the EDIT

IMAGE soft key.

2. Press the SYNC soft key.

SYNC

+00

Sync entry window

3. Enter a sync value that displays the dead sector straightly. If the dead

sectors appears as in the left-hand figure in example of phasing signals in the
illustration above, enter a larger value and for the right-hand figure, enter a
smaller value. The setting range is –50 to +50.

4. Press the ENTER soft key.
5. Press the RETURN soft key several times to return to the standby display.

2.5.3 Noise

rejection

If noise speckles appear on the image, turn on the noise rejector as below to
remove the noise.

1. With a facsimile image displayed (see paragraph 2.4), press the EDIT

IMAGE soft key.

2. Press the NOISE REJECT soft key.

NOISE REJECT

¡

¡

¡

¤

OFF
LOW
MEDIUM
HIGH

Noise rejector options

3. Rotate the [ENTER] knob to choose the noise rejection level desired. HIGH

provides the greatest degree of noise rejection.

4. Press the ENTER soft key.
5. Press the RETURN soft key several times to return to the standby display.