2 general troubleshooting (cont.) – Frymaster YPF95 User Manual

Page 20

Advertising
background image

YPF95 SERIES PORTABLE FILTRATION SYSTEMS

CHAPTER 6: TROUBLESHOOTING

6-2

6.2 General Troubleshooting (cont.)


Pump won't

start.

-

Tripped circuit breaker.

-

Incorrect or no line voltage.

Pump stops

during filtering

process.

-

Allow filter unit to cool for at least 45 minutes and

then press the pump reset button on the side of the
filter.

-

Turn filter pump "OFF". Allow oil to cool then empty

pan. Verify filter paper is clean and properly
installed. Refill pan and restart process.

Pump starts

and abruptly

stops.

-

Reset circuit breaker.

-

Pump is blocked or wiring is loose. Call FASC for

service.

-

Filter pan suction tube is blocked. Use a thin, flexible

wire to unclog.

-

Motor failed; call FASC for service.

Pumping is

erratic.

-

Verify that filter paper is properly installed under

hold-down ring.

Oil not being

returned to

frypot.

-

Solidified oil or sediment is likely clogging the filter

hose. Clear hose.

-

Clogged filter paper. Scrape off excess sediment or

replace filter paper.