Control channel 5 - Gobo rotation

DMX-value

Feature

0-15

No rotation

16-135

Forwards gobo rotation with decreasing speed

136-255

Backwards gobo rotation with increasing speed

Control channel 6 - Shutter, strobe

DMX-value

Feature

0-5

Shutter closed

6-128

Dimmer control

129-131

Reset (after 3-5 seconds)

132-139

No function (Shutter open)

140-199

Strobe effect with increasing speed

200-249

Random strobe effect with increasing speed

250-255

No function (Shutter open)

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.

The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.

The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not

be corroded.

2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,

trussing).

3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material

abrading or damages) and must not rotate with unbalances.

4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or

sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.

Disconnect from mains before starting maintenance operation!

DANGER TO LIFE!

We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!

The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!

CAUTION!

The objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light-output very quickly. The cooling-fans should be cleaned monthly.

The gobos may be cleaned with a soft brush. The interior of the fixture should be cleaned at least annually
using a vacuum-cleaner or an air-jet.

The dichroic colour-filters, the gobo-wheel and the internal lenses should be cleaned monthly.

To ensure a proper function of the gobo-wheel, we recommend lubrication in six month intervals. The