Wiring – Furuno IF-NMEASC User Manual

Page 10

Advertising
background image

2

2.

WIRING

Open the IF unit with your hands, detach the shield cover and connect external equipment, refer-
ring to the illustration below and the interconnection diagram. Cables are mainly connected to the
unit with WAGO connectors. See the instructions below for how to attach wiring to the connectors.
The opener for the WAGO connectors is attached to the inside of the inner cover. Fix cables to
their respective cable posts with cable ties (supplied). Run a ground wire (IV-2.0sq., local supply)
between the ground terminal and ship's grounding bus. Supply power from breaker on mains
switchboard.

Power cable

J8 (Analog)

J7 (SC-30 Sensor)

J5 (NMEA 0183)

J4 (NMEA 0183)

J3 (AD-10)

Ground terminal

Power cable:

AWG 16-20, and diameter less than 10 mm

(JIS* cable DPYC-1.5 or equivalent)

All other cables: AWG 16-28, shield, twisted, and diameter less than 8 mm

(JIS* cable TTYCS-1, TTYCS-4 or equivalent)

Cable
post

Fix cable to cable post with
two cable ties (supplied).

Cable tie

Cable post

Recommended Cables

How to wire WAGO connector

How to fix cable to cable post

1. Insert opener.
2. Press opener.
3. Insert core.
4. Release opener

.

Opener

Wire

Twist

* Japan Industry Standard cable