2 replacing the fuse, 3 troubleshooting – Furuno IF-NMEASC User Manual

Page 19

Advertising
background image

5. MAINTENANCE, TROUBLESHOOTING

11

5.2

Replacing the Fuse

The 2A fuse inside the unit protects it from overcurrent and equipment fault. If the power cannot
be turned on, have a qualified technician check the fuse. If the fuse has blown, find out the cause
before replacing it. If it blows again, contact your dealer for advice.

5.3

Troubleshooting

This section provides simple troubleshooting procedures which the user can follow to restore nor-
mal operation. If normal operation cannot be restored, do not attempt to check inside the equip-
ment. There are no user-serviceable parts inside.

Simple troubleshooting procedures

Item

Type

Code No,

Fuse

FGMB 125V 2A PBF

000-157-479-10

Symptom

Possible trouble

Remedy

Power cannot be
turned on

• Power at switchboard is turned

off.

• Disconnected or damaged

power cable.

• Blown fuse.

• Check if power is on at switchboard.

• Check if power cable is disconnected

or damaged.

• Have a qualified technician check the

fuse.

Data is not received
from SC-30

• Signal cable between the SC-

30 and this equipment is dam-
aged or disconnected.

• SC-30 is no received satellite

signal.

• Check if sensor cable is disconnect-

ed or damaged.

• See the SC-30's operator's manual.

Data is not received
at external equip-
ment

• Disconnected or damaged in-

terconnection cable.

• Output settings may be incor-

rect.

• Check if cable is disconnected or

damaged.

• Have a qualified technician check the

settings.

Heading, pitch or roll
data is not correct

• Offsets entered in this equip-

ment may be incorrect.

• Have a qualified technician check the

settings.

Advertising