Specifications, Furuno, Specifications of interface unit if-nmeasc – Furuno IF-NMEASC User Manual

Page 23

Advertising
background image

FURUNO

IF-NMEASC

SP - 1

E7265S02A-M

SPECIFICATIONS OF INTERFACE UNIT

IF-NMEASC

1 INPUT

PORT

NMEA 2000*, for data I/O between FURUNO satellite compass SC-30

* NMEA 2000 is a registered trademark of the Nationa l Marine

Electronics Association.

2 OUTPUT

PORT

NMEA 0183: Two ports (HDT, HDG, HMD, ATT*, HVE*, VTG, GGA,

RMC, ZDA)

* ATT (heading, pitch, roll) and HVE (heave) are FURUNO

proprietary sentences.

AD-10: One port

Analog: One port (pitch, roll)

3

NMEA 0183 OUTPUT INTERVAL

HDT, HDG, HDM, ATT, HVE: 25ms, 100 ms, 200 ms, 1 s, 2 s

VTG, GGA, RMC, ZDA: 1 s, 2 s

4 POWER

SUPPLY

12-24 VDC: 1.0-0.6 A

5 ENVIRONMENTAL

CONDITIONS

5.1 Ambient Temperature

-15°C to +55°C

5.2 Humidity

Less than 95% at 40°C

5.3 Waterproofing

IP20

5.4 Vibration

- From 2 Hz to 5 Hz to up to 13.2 Hz with an excursion of ±1 mm ±10%

-13.2 Hz to 100 Hz with a constant maximum acceleration of 7 m/s

2

6 COATING

COLOR

N2.5

Advertising