Table A-25. 2645A DC Voltage Resolution and Repeatability Specifications

Resolution

Range

Slow

Fast

90 mV

3 µV

6 µV

300 mV

10 µV

20 µV

3V

100 µV

200 µV

30V

1 mV

2 mV

50V/300V*

10 mV

20 mV

* 300V range applies to channels 1 and 11 only.

Table A-26. 2645A DC Voltage Accuracy Specifications

Accuracy, 3

σ

±

(% input + V)

18

º

C to 28

º

C

-10

º

C to 60

º

C

Range

90 Day

1 Year

1 Year

Slow

Fast

Slow

Fast

Slow

Fast

90 mV

.01%+20 µV

.01%+50 µV

.013%+23 µV

.013%+50 µV

.042%+52 µV

.042%+130 µV

300 mV

.01%+40 µV

.01%+90 µV

.013%+49 µV

.013%+93 µV

.042%+104 µV

.042%+234 µV

3V

.01%+.3 mV

.01%+.6 mV

.013%+.38 mV

.013%+.64 mV .042%+.78 mV

.042%+1.56 mV

30V

.01%+4 mV

.02%+8 mV

.013%+4.9 mV

.026%+9.5 mV .042%+10.6 mV .084%+20.3 mV

50V

.01%+30 mV .04%+60 mV .013%+40 mV

.052%+64 mV

.042%+78 mV

.168%+156 mV