FUJITSU Mainboard D1931 User Manual

Page 46

Advertising
background image

Error messages

36 - English

A26361-D1931-Z120-1-7419, Edition 1

Missing or invalid NVRAM token

Switch the device off and on again. If the message is still displayed, please contact your sales
outlet or customer service centre.

Monitor type does not match CMOS - RUN SETUP

Correct the entry for the monitor type in the Main menu of the BIOS Setup.

On Board PCI VGA not configured for Bus Master

In the BIOS Setup, in the Advanced menu, submenu PCI Configuration, set the Shared PCI Master
Assignment
entry to VGA.

One or more RDRAM devices are not used

One or more RDRAM devices have bad architecture/timing

One or more RDRAM devices are disabled

Contact your system administrator or contact our customer service centre.

Operating system not found

Check the entries for the hard disk drive and the floppy disk drive in the Main menu and the

entries for Boot Sequence submenu of the BIOS Setup.

Parity Check 1

Parity Check 2

Switch the device off and on again. If the message is still displayed, please contact your sales
outlet or customer service centre.

Previous boot incomplete - Default configuration used

By pressing function key F2 you can check and correct the settings in BIOS Setup. By

pressing function key F1 the system starts with incomplete system configuration. If the
message is still displayed, please contact your sales outlet or customer service centre.

Real time clock error

Call the BIOS Setup and enter the correct time in the Main menu. If the message is still

displayed, please contact your sales outlet or customer service centre.

Service Processor not properly installed

The server management controller has not been correctly installed. If the message is still
displayed, please contact your sales outlet or customer service centre.

Storage Extension Group = xy

Configuration error, x Storage Extensions(s) found, configured are y

SE(s).

Device List: k1, k2 ...

The specified number of storage expansion units (SEs) in the BIOS Setup menu Server - Storage
Extensions - Number of connected SE
is incorrect. Check how many SEs within the group are

connected at the server and change the setting in BIOS Setup. Check whether you have

assigned the same device ID twice.
xy = Group number
x = Number of SEs found on the communication bus
y = Number of SEs entered in Number of connected SE

k1, k2 ... = Device ID of the storage extensions found

Advertising