Frymaster BK1814E User Manual

Page 11

Advertising
background image

2-2

DANGER

Do not attach an apron drainboard to a single fryer. The fryer may become unstable,
tip over and cause injury. The appliance area must be kept free and clear of
combustible material at all times.

DANGER

Building codes prohibit a fryer with its open tank of hot oil being installed beside an
open flame of any type, including those of broilers and ranges.


In the event of a power failure, the fryer(s) will automatically shut down. If this occurs, turn the
power switch OFF. Do not attempt to start the fryer(s) until power is restored.

2.1.1 Clearance

and

Ventilation


This appliance must be kept free and clear of combustible material.

A clearance of 6 inches (15cm) must be provided at both sides and back adjacent to combustible
construction. A minimum of 24 inches (61cm) should be provided at the front of the equipment for
servicing and proper operation.

WARNING

Do not block the area around the base or under the fryers.


2.1.2 Electrical

Grounding Requirements


All electrically operated appliances must be grounded in accordance with all applicable national and
local codes, and, where applicable, CE codes. All units (cord connected or permanently connected)
should be connected to a grounded power supply system. A wiring diagram is located on the inside
of the fryer door. Refer to the rating plate on the inside of the fryer door for proper voltages.


2.1.3 Australian Requirements

To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other
relevant statutory regulations.

Advertising