Installation – FMI VF48H(I)(R)A User Manual

Page 6

Advertising
background image

www.fmiproducts.com

124386-01A

6

Figure 6 - Lineal Gain

LINEAL GAIN

PART NO.

DESCRIPTION GAIN (IN)

48" Plantation

Fireplace

66

1

/

2

"

12-12DM

12-12HT

Pipe Section

10

5

/

8

"

18-12DM

18-12HT

Pipe Section

16

5

/

8

"

24-12DM

24-12HT

Pipe Section

23

5

/

8

"

36-12DM

36-12HT

Pipe Section

34

5

/

8

"

48-12DM

48-12HT

Pipe Section

46

5

/

8

"

RLT-12D

RLT-12HT

Round

Termination

7

3

/

4

"*

STL-12D

Square Chase-

Top with Slip

Section

7" to 15"*

* The lineal gain for the terminations is mea-

sured to the flue gas outlet height.

Hemmed

End

12

3

/

8

"

Stainless

Inner Pipe

15" Galvanized

Outer Pipe

ASSEMBLY AND INSTALLATION OF

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of

a galvanized outer pipe, a stainless steel in-

ner flue pipe and a wire spacer. Pipe sections

must be assembled independently as chimney

is installed. When connecting chimney directly

to fireplace, inner flue pipe section must be

installed first with lanced side up. Outer pipe

section can then be installed over flue pipe

section with hemmed end up. Press down

on each pipe section until lances securely

engage hem on fireplace starter. Wire will

assure proper spacing between inner and

outer pipe sections.

Continue to assemble chimney sections as

outlined above, making sure both inner and

outer pipe sections are locked together. When

installing double wall snap-lock chimney to-

gether, it is important to assure joint between

chimney sections is locked. Check by pulling

chimney upward after locking. Chimney will

not come apart if properly locked. It is not

necessary to add screws to keep chimney

together (exception, see Figure 9, page 8).

Figure 5 - Outside Air Kit

Secure to Collars with Metal Tape, Screws

or Straps (Min. of 1/4" x 20" in size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

Vent Hood

Required for

Wall Installation

Air Inlet

Eyebrow

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.

The maximum height for the

air vent can not exceed 3 feet

below the flue gas outlet of the

termination.

CHIMNEY PIPE

FMI PRODUCTS, LLC chimney system

consists of 12", 18", 24", 36"' and 48" snap-

lock, double-wall pipe segments, planned

for maximum adaptability to individual site

requirements. Actual lengths gained after fit-

ting overlaps must be taken into consideration

(lineal gain) and are given in lineal gain chart

(see Figure 6). Lineal gain is the actual mea-

surable length of a part after two or more parts

are connected. For Canada, use chimney parts

designated "HT".

WARNING: The opening in the

collar around the chimney at the

top of the fireplace must not be

obstructed. Never use blown insula-

tion to fill the chimney enclosure.

INSTALLATION