Air conditioner use, Warning – Friedrich CP18C30 User Manual

Page 11

Advertising
background image

11

11

3. Connect green ground wire to cabinet base with ground

screw.
Position ground wire pointing straight up. Put excess ground

wire between coil and air conditioner cabinet.

4. Push front panel straight on and then lower it slightly to lock it

into place.

5. Using 2 - #10 x ³⁄₈" round-head screws, attach bottom front of

panel.

NOTE: For through-the-wall installations, if needed, install

molding around room side of cabinet.

6. Plug into a grounded 3 prong outlet.
7. Press RESET on the power supply cord.

Air Conditioner Use

Operating your air conditioner properly helps you to obtain the

best possible results.
This section explains proper air conditioner operation.
IMPORTANT:

If you turn off the air conditioner, wait at least 3 minutes

before turning it back on. This prevents the air conditioner

from blowing a fuse or tripping a circuit breaker.

Do not try to operate your air conditioner in the cooling mode

when outside temperature is below 65°F (18°C). The inside

evaporator coil will freeze up, and the air conditioner will not

operate properly.

NOTE: In the event of a power failure, your air conditioner will

operate at the previous settings when the power is restored.

A. Green ground wire
B. Ground screw

WARNING

Electrical Shock Hazard

Connect green ground wire to ground screw.
Failure to do so can result in death or electrical shock.

A

B

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.