2. Using #10 x ⁷⁄₈" pan-head Phillips screws, attach bracket to

cabinet. Repeat for other bracket.

3. Turn the adjustment bolt for each bracket until the bolt

touches the wall.

4. Turn the locking nut on adjustment bolt to lock in position.

Complete Installation

1. Insert seal behind the top of the lower window sash and

against the glass of the upper window.

2. Place one window-lock bracket on top of lower window and

against upper window sash on each side of window.

3. Use a ³⁄₃₂" drill bit to drill a starter holes through the holes in

each bracket into the window sash.

4. Attach both window-lock brackets to window sash with #10 x

³⁄₄

" round-head screws to secure window in place.

Through-the-Wall Cabinet Installation

NOTES:

Handle air conditioner gently.

Be sure your air conditioner cabinet does not fall out of the

opening during installation or removal.

The place where the power cord exits the air conditioner

should be no more than 4 ft (122 cm) from a grounded

3 prong outlet.

It is the customer's responsibility and obligation to have this

product installed by a qualified technician familiar with

through-the-wall room air conditioner installations.

Do not block the louvers on the front panel.

Do not block the louvers on the outside of the air conditioner.

Option 1—Wood, metal or plastic molding

When using a wood, metal or plastic molding, the wood frame

should line up with inside wall as shown.

Option 2—Plastered wall with no molding

If the plastered wall is to be flush with the cabinet and no molding

is used, the wood frame must be set ¹⁄₂" (13 mm) into the inside

wall.

Install Wood Frame

1. Construct wood frame. See “Location Requirements” for

dimensions.

2. Measure outside width and height of frame to determine wall

opening dimensions.

3. Cut opening through the wall. Remove and save insulation.

NOTES:

Dimension for depth depends on wall thickness and type

of molding.

Do not block louvers in air conditioner cabinet.

A. Support bracket
B. Locking nut

C. Adjustment bolt

A

B

C

A. Window lock brackets
B. Window rail seal

C. Upper window glass

A

B

C

A

A. Molding
B. Inside wall

C. Wood frame
D. Louvers

A

C

B

D

A. Plastered wall
B. Inside wall

C. Wood frame
D. Louvers

D

A

C

B

Advertising