Troubleshooting guide, Problem corrective action – Frymaster Cool Zone Electric Fryer User Manual

Page 16

Advertising
background image

14

6. TROUBLESHOOTING GUIDE


The problems and possible solutions given below cover those most commonly encountered by
operators.

FOR DETAILED TROUBLESHOOTING AND SERVICE-RELATED INFORMATION, CALL
THE DEAN SERVICE HOTLINE AT 1-800-551-8633 (USA/Canada only) or 1-318-865-1711.

PROBLEM CORRECTIVE

ACTION

Operator hears click sound
when the temperature
controller dial is turned but
vessel remains cold. No
evidence that elements are
warming the vessel.

With the power switch “ON”:

1. Manually reset the high temperature limit switch (push red button

on the panel above the drain valve). See Figure 6-1.

2. Check for tripped branch or main circuit breakers or blown fuses.

Poor temperature control
on the cold side or hot side;
excessive warm-up time;
temperature recovery is
slow or inadequate when
vessel is loaded; uneven
heating; excessive
temperature overshooting

during warm-up; scorching;
overheating; or high limit
switch must be reset often.

Check thermostat adjustment:

1. Check that the thermostat bulb/probe in the vessel has not been

knocked loose from its operating position. It should be clamped
to the second element with 1,5 mm (1/16 inch) spacing. See
Figure 6-2.


2. Place the sensing bulb of a high quality immersion thermometer

about 38 mm (1-1/2 inches) above the thermostat sensing bulb
and set the temperature controller dial to 177°C (350°F).


3. Wait at least 30 minutes for the oil temperature to stabilize.

4. If temperature is not within +/- 5°C (10°F) of the dial setting, call

service for a new operating thermostat/temperature controller.

















High Limit

Reset Switch

Sensing Bulb in

Fryer Vessel

Drain
Valve

Figure 6-1

Figure 6-2