Falcon SUP1.0K-1C User Manual

Page 11

Advertising
background image

2.

Input Fuse - Always replace with the same fuse type and rating.

3.

Inlet - for connection of incoming power cord.

4.

UPS output receptacles - The top NEMA type receptacles will be

found on all domestic (120V) models.
IEC type receptacles will be found on
international (230V) models.

5.

DB-9 RS-232 computer interface connector.

6.

Surge protected, RJ11 type telephone jacks - To provide surge
protection for your fax, modem or other telecommunications devices.
Connect the incoming telephone line to one of the jacks. Then,
connect the fax, modem or other device to be protected to the other
jack.

7.

Audible Alarms - Reference the following table.

ALARM

PERIOD

STATUS INDICATED

No Beep

Utility Good

No Beep

Utility Loss

UPS OFF

No Beep

LCD flashes every 2 seconds

Timer on, refer to operation section

#9

No Beep

Continuously

Normal (utility good)

One beep every 4 seconds

Operating on battery mode

(no load)

Beep

(Can be silenced)

2 beeps every 4 seconds

Operating on battery mode

(loaded)

Beep

(Cannot be

silenced)

4 beeps per second

Operating on battery mode

(LOW BATTERY)

UPS

TURNED ON

Beep

8 beeps per second

DEFECTIVE BATTERY