Optional gas line installation – FMI WCM-42G User Manual

Page 13

Advertising
background image

www.fmiproducts.com

122271-01D

13

Gas line hook up should be done by your

supplier or a qualified service person.
Note: Before you proceed, make sure your

gas supply is turned off.
Use only a 1/2" black iron pipe and appropri-

ate fittings.
1. Remove knockout indentation on refrac-

tory or firebrick wall located above refrac-

tory hearth floor. Knockout indentation

must be firmly tapped with any solid object

such as a 1/2" dowel until it is released.

Remove fragmented portions of refractory

(see Figure 21).

2. Remove gas line cover plate located on

either side of fireplace and pull out insula-

tion from gas line conduit sleeve. Save

insulation for reuse. Replace screws.

3. Run a 1/2" black iron gas line into fireplace

through the rear at gas line conduit sleeve (if

using a raised platform, add height). Provide

sufficient gas line into fireplace chamber for

fitting connection (see Figure 22).

Note: Secure incoming gas line to wood

framing to provide rigidity for threaded end.

4. Repack insulation around gas line and into

sleeve opening. Seal any gaps between

gas line and refractory knockout hole with

refractory cement or commercial furnace

cement, Install the gas appliance or cap-off

gas line if desired.

CAUTION: All gas piping

and connections must be tested

for leaks after the installation

is completed. After ensuring

that the gas valve is on, apply

soap and water solution to all

connections and joints. Bubbles

forming show a leak. Correct

all leaks at once. DO NOT USE

AN OPEN FLAME FOR LEAK

TESTING AND DO NOT OPER-

ATE ANY APPLIANCE IF A LEAK

IS DETECTED. LEAK TESTING

SHOULD BE DONE BY A QUALI-

FIED SERvICE PERSON.

WARNING: Do not operate an

unvented gas log set in this fire-

place with the chimney removed.

Figure 21 - Gas Line Access

Side

Firebrick

Finished

Side

Brick with

Access

Hole

Outside of

Fireplace

Gas Line

Conduit

Insulation

Gas

Conduit

Cover

1/2" Dowel

Seal

Opening

with

Refractory

Cement

Outside of

Fireplace

Gas Line

Conduit

Repack

Insulation

Incoming

1/2" Black

Iron Pipe

Side

Firebrick

Finished

Side

Provide Enough

Threaded

End for Fitting

Connection

Figure 22 - Gas Line Installation

Remove

Knockout

opTional gaS line inSTallaTion

If you install a decorative gas appliance

(vented gas log), the decorative gas appliance

must comply with the Standard for Decorative

Gas Appliance for Installation in Solid Fuel

Burning Fireplaces, ANS Z21.60 or Z21.84

and shall also be installed in accordance with

the National Fuel Gas Code, ANSI 7223NFPA

54 latest edition.

WARNING: If the fireplace

has been used for wood burning,

the firebox and chimney must be

cleaned of soot, creosote and

ashes be a qualified chimney

cleaner. Creosote will ignite if

heavily heated.

WARNING: When using a

decorative vented gas log, the

damper must be removed or per-

manently locked in the fully open

position and the glass doors must

be in the fully open position.