VenTing inSTallaTion

Continued

OFFSET RISE

CHIMNEY LENGTH

A

B

12" 18" 24" 36" 48"

4

3

/

8

"

16

3

/

8

"

ELBOW SET ONLY

9

3

/

4

"

25

1

/

2

"

1

12

3

/

4

" 30

3

/

4

"

1

15"

34

3

/

4

"

1

18"

40"

1

1

21

1

/

4

" 46

1

/

4

"

1

23

3

/

4

" 49

1

/

4

"

1

1

27

3

/

4

" 56

3

/

4

"

1

30"

60

3

/

4

"

1

1

33"

66"

1

36"

71"

1

1

38

1

/

4

"

75"

2

41

1

/

4

" 80

1

/

4

"

1

1

1

45"

86

3

/

4

"

2

46

3

/

4

" 89

1

/

2

"

1

1

1

51"

97"

1

1

53

1

/

4

"

101"

2

56

1

/

4

" 106

1

/

4

"

2

59

1

/

4

" 111

1

/

2

"

1

1

1

61

3

/

4

" 115

1

/

2

" 1

2

64

3

/

4

" 120

3

/

4

"

1

2

68

1

/

4

"

127"

2

1

70"

130"

1

1

2

74

1

/

4

" 137

1

/

2

" 1

2

1

76

3

/

4

" 141

1

/

2

"

1

2

1

79

3

/

4

" 146

3

/

4

"

4

OFFSET CHART (22-50 FT. SYSTEM HEIGHT)

Figure 11 - Ceiling Support Pipe

12S-12DM

2" Min.

Straps

Straps

Straps

Straps

Detail A

Return Elbow

Detail B

Angle Firestop

See Detail A

See Detail B

Continue to assemble chimney sections as

outlined above, making sure that both the

inner and outer pipe sections are locked to-

gether. When installing double wall snap-lock

chimney together, it is important to assure

the joint between the chimney sections is

locked. Check by pulling chimney upward

after locking. The chimney will not come apart

Figure 10 - Elbow Offset

B

A

Screws

if properly locked. It is not necessary to add

screws to keep the chimney together (excep-

tion, see Figure 10).

USING ELBOW OFFSETS (30E-12DM)

1. To achieve desired offset, you may install

combinations of 12", 18", 24", 36" and 48"

length of double wall pipe (see offset chart

and Figure 10).

2. Chimney weight above offset rests on

return elbow. Straps must be securely

nailed to rafters or joists (see Figure 11,

details A and B).

3. Maximum length of pipe between sup-

ports (return elbow or 12S-12DM) is 6'

of angle run. Maximum of two 6' angle

run sections per chimney system (see

Figure 12, page 10).

4. All pipe connections between the offset

and return must be secured with two

screws on the outer pipe only (see

Figure 10). Do not penetrate the inner

stainless.