5.4 Self Test

The self test facility checks the keyboard,
ROM and RAM for proper operation.
1. Press the [MENU] key.
2. Select “OTHER MENU”.
3. Select “23. Self Test” and press the

[ACQ/ ENTER] key. The following display
appears.

ARP-10 TEST

ROM OK 18990871xx
RAM OK
SPEED OK NAV 0.0KT
COURSE OK 167.6

°

TRIGGER NG
VIDEO NG
BP OK
HP OK
MIN-HIT 0003
SCAN-TIME 0854
MAN-ACQ 00
AUTO-ACQ 00
FE-DATA1 0000
FE-DATA2 0000

[Self Test]

Key tset: Press each key and
check on-screen indication
lights.

Program No.: 0359222-XX.XX
ROM : OK
RAM : OK
EEPROM : OK
Hours in use : 000006.9H
Tx hours: 000001.1H
OK

<Press MENU for OTHERS menu>

XX: Program Version No.

Figure 5-1 Self test screen


4. The ROM and RAM are automatically

checked. If NG (No Good) appears to
the right of ROM or RAM indication,
contact your dealer for advice. ARP-10
TEST results appear only when optional
ARP-10 board is mounted.


5. To check the keyboard. Press any key

except the omnipad, ACQ and power
keys. Its corresponding location on the
display lights in black if the key is
operating properly.

6. Press the [ACQ] key to check the

display circuit. The following pattern
should appear.

Figure 5-2 Test pattern

7. Press the [MENU] key to show the

brilliance adjustment menu.

8. To escape from the selftest, press the

[MENU] key.

5.5 Life Expectancy of

Magnetron


The following table shows the life
expectancy of the magnetrons.

Table 5-3 Life expectancy of magnetrons

Model Type

Code

no.

Life

expectancy

E3571 000-146-867

MG4004 000-158-895

1832/

1932

MAF1421B

000-158-786

-10

MAF1422B

000-146-871

1942

MG5389 000-135-146

2,000-3,000

hours

(Including

stand-by)

Advertising