Magnetron heater voltage, Setting a blanking area – Furuno 1832 User Manual

Page 49

Advertising
background image

35

Magnetron heater voltage

Magnetron heater voltage is formed at the MD
Board of the antenna unit and preadjusted at
the factory for use with any length of signal
cable. Therefore no adjustment is required.
However, verify heater voltage by following
the procedure below.

1. Turn on the radar (if it is not already on)

and set it in stand-by.

2. Open the antenna housing (radome) cover.

Connect a multitester, set to 10 V DC range.

3. Close the antenna housing cover and tighten

the fixing bolts.

Setting a blanking area

When the antenna is installed at a close dis-
tance in front of the wheelhouse, the radar
should be set not to transmit within that area.
No echoes appear in the blanking areas.

1. Select "7. Dead Sector".

2. Press the [ENTER] key.

3. Operate the omnipad to enter starting point

of area (in figures).

4. Press the [ENTER] key.

5. Operate the omnipad to enter ending point

of area (in figures).

6. Press the [ENTER] key.

Area of no
transmission

Figure 6-27 Blank areas where

transmission is suspended

This area can be turned on/off on the OTHER
MENU. For detail, see the description on page
18.

Note: This setting should be done after other
adjustments are finished.

Model

Check Point

Rating

Adjustment
point

M1832

TP802 #4, #6 on
PTU Board

7.4~7.6V

R106

M1932

TP803 #4, #6 on
MD Board

7.4~7.6V

VR801

M1942

TP803 #4, #6 on
MD Board

7.5~7.7V

VR801

Advertising