Registering procedure, Recalling procedure, Canceling the recalling – Furuno CSH-5 MARK-2 User Manual

Page 29: Recommended settings

Advertising
background image

23

Registering Procedure

1. Press the

MENU

key.

2. Rotate the

RANGE

control to select FUNC KEY PROG.

3. Rotate the

GAIN

control to select FUNC1 or FUNC2.

4. Press the

TX

key. Each time the TX key is pressed, the current

settings in the scan menu and E/S menu are recorded.

When FACTORY is selected, the default value is displayed.

Recalling Procedure

1. Press

F1

or

F2

. Presetting function is recalled and function indi-

cation (LED lamp) lights.

Canceling the recalling

1. Press

F1

or

F2

again. The LED lamp goes off.

Recommended Settings

We recommend the function key be set as follows,

TX OUTPUT

PULSELENGTH

TX CYCLE

TVG NEAR

TVG FAR

HOR BEAM ANGLE

VER BEAM ANGLE

RES COL CURVE

COL EMPHASIS

8

7

10

5

5

NARROW

NARROW

LINEAR

3

For detection of surface fish school

TX OUTPUT

PULSELENGTH

TX CYCLE

TVG NEAR

TVG FAR

HOR BEAM ANGLE

VER BEAM ANGLE

RES COL CURVE

COL EMPHASIS

8

8

10

6

7

NARROW

WIDE

2

3

For detection of midwater fish

TX OUTPUT

PULSELENGTH

TX CYCLE

TVG NEAR

TVG FAR

HOR BEAM ANGLE

VER BEAM ANGLE

RES COL CURVE

COL EMPHASIS

7

5

10

5

6

NARROW

WIDE

3

1

For detection of bottom fish

Advertising