Conti test, Panel test, Sio test – Furuno CSH-5 MARK-2 User Manual

Page 61

Advertising
background image

55

Conti Test

This is a continuous test of the Display and Transceiver Units. Addi-
tionally checked devices are DROM and DRAM.

CONTI TEST

MAIN 105-0541-XXX 105-0542-XXX

ROM

= OK

RAM

= OK

P.W

= OK

DROM

= OK

DRAM

= OK

DPRAM

= OK

TRX

105-

∗∗∗∗

-XXX 105-

∗∗∗∗

-XXX

ROM

= OK

RAM

= OK

DROM

= OK

I/F

105-0267-XXX
ROM

= OK

RAM

= OK

DPRAM

= OK

GYRO

= OK

LOG

= OK

PRESS [MENU] 2 or 3 SECONDS TO STOP SELFCHECK

Not displayed if interface module
CSH-5060 is not provided.

∗∗∗∗:

0635

e

107kHz

0644

e

85kHz

Panel Test

This test checks the controls on the front panel and the control box
for proper operation.

PANEL TEST

0 0
0 0

• •

• •

0 0 0 0 0 0

0 0

X = 0 0

7 3 0 0

Y = 0

0 0

PRESS [MENU] 2 or 3 SECONDS TO STOP SELFCHECK

Main Panel
Press each control one by one.
The figure should change if the
control is functioning properly.

Control Box

Repeat the above procedure.

SIO Test

This test checks the input/output parts of the Transceiver Unit. The
results of the test are indicated as OK or NG.

SIO TEST

MAIN SIO1 = OK

SIO2 = OK

I/F

SIO-NAV = NG
SIO-CI

= NG

PRESS [MENU] 2 or 3 SECONDS TO STOP SELFCHECK

SIO1: Checks communication line

between display and
transceiver unit.

SIO2, SIO-NAV and SIO-CI check
communication line between interface
module (option) and display unit.
Short-plug is required to conduct this
test.

Advertising