Warning, Overvoltage warning, Unretracted transducer warning – Furuno CSH-5 MARK-2 User Manual

Page 36: Overvoltage, Xdcr not retracted

Advertising
background image

30

9. WARNING

Overvoltage Warning

If the supply voltage rises about 20% to over the rated value, the
overvoltage detection circuit is actuated. The following warning flick-
ers at the center of the screen and an alarm sounds.

OVERVOLTAGE!

If this occurs, retract the transducer, turn the

POWER

off and check

the ship’s mains (and the stepdown transformer if provided).

Unretracted Transducer Warning

When the transducer can not be completely retracted within 35 sec-
onds after pressing the

TRANSDUCER

” switch, the following

warning flickers at the center of the screen and an alarm is released.

XDCR NOT RETRACTED!

If this occurs, do the following.

1. The

POWER

switch can not be turned off because the transducer

can not be retracted. Turn off the main breaker for the transceiver
unit to stop operation.

2. Confirm that the net is not entwined around the transducer.

3. Confirm that the breaker inside the raise/lower control box mounted

on the hull unit is “ON”.

4. Check the mains fuse in the transceiver unit.

5. Apply the power again and confirm that the transducer is retracted

into the tank. If not, the main shaft of the hull unit may be bent.
Cut off the power again and manually raise the transducer up to
the highest position by using the hand crank attached to the hull
unit.