2-3

2.4

Connecting to the Electrical Power Supply

DANGER

This unit must be connected to the voltage and phase specified on the rating and serial

number plate located on the inside of the equipment door. To determine the appropriate

wire size, refer to the POWER REQUIREMENTS chart at the bottom of this page.


1. If the unit is not equipped with an installed power cord, open the door and remove the contactor

box cover. Position the unit to gain access to the rear and remove the lower back panel.


2. Insert an appropriately rated power cord into the rear of the contactor box and make connections

in accordance with the applicable wiring diagram on the following page. Install a strain relief on
the power cord and replace the lower back panel and contactor box cover.


3. Attach a plug that complies with national and/or applicable local codes to the free end of the

electrical power cord and plug the unit into an appropriate outlet.

POWER REQUIREMENTS

Use copper wire ONLY, suitable for at least 170ºF (75ºC)

Volts Phase Watts

Amps

(per leg)

Minimum

Wire Size

200

Single

7400

37

AWG 6 (4.1 mm)

208

Single

8000

39

AWG 6 (4.1 mm)

220

Single

7300

34

AWG 6 (4.1 mm)

230

Single

8000

35

AWG 6 (4.1 mm)

240

Single

8000

34

AWG 6 (4.1 mm)

200

3P – Delta

7400

22

AWG 8 (3.3 mm)

208

3P – Delta

8000

23

AWG 8 (3.3 mm)

220

3P – Delta

7300

20

AWG 8 (3.3 mm)

230

3P – Delta

8000

21

AWG 8 (3.3 mm)

240

3P – Delta

8000

20

AWG 8 (3.3 mm)

200

3P – Wye

7400

13

AWG 8 (3.3 mm)

220

3P – Wye

7300

12

AWG 8 (3.3 mm)

230

3P – Wye

7400

11

AWG 8 (3.3 mm)

NOTE: This equipment is field-convertible between single phase and three phase.

Advertising
This manual is related to the following products:

8C, 8BC