6-9

5. If the unit is equipped with a pressure regulator, disconnect the regulator from the water line at

the outlet side.

Disconnect at this

compression fitting.

6. Remove the screws securing the fluecap assembly to the back panel of the cabinet and remove

the assembly from the unit. On 8SMS units, remove the connecting strip disconnected in Step 4.

Remove the screws securing the flue

cap to the back panel of the cooker.

7. Using an assistant, lift the cookpot or rinse tank up and out of the cabinet.

8. Recover the components from the failed cookpot or rinse tank and install on the replacement

cookpot or rinse tank.


9. Reverse steps 1 through 10 to complete the procedure.