Frymaster 8SMS User Manual

Page 37

Advertising
background image

6-12

The contactor block is the terminal block to which the element leads are connected and where
actual contact is made between the leads and the line voltage. Built into the contactor block is a coil
(electronic switch) that closes when a ground for the 24VAC from the transformer is supplied by the
controller calling for heat. When it closes, contact is made between the incoming line voltage and
the element leads.

The element is a resistive heating device. That is, when voltage is applied to the element, the
element gets very hot due to its resistance to current flow through it. The heat generated is
transferred directly to the water in which the element is immersed.

The controller is the interface between the operator and the other components of the equipment. In
the water heating system, its function is to control the application of line voltage to the heating
element via the contactor coil.

Troubleshooting the water heating system consists of checking the above components for proper
operation, as detailed in the troubleshooting diagrams on the next page.

6.4.3 Technician Troubleshooting Guides

TROUBLESHOOTING

THE AUTOFILL

SYSTEM

What is the

problem?

Solenoid valve
does not close

when water

reaches upper

water level sensor.

Solenoid valve

does not open

when water is

below upper water

level sensor.

Is 24VAC

present at pin 6

of the 15-pin

plug?

Is 24VAC

present at pin 6

of the 15-pin

plug?

Check for shorting

of sensor to ground. If

sensor is not shorted,

computer has failed.

Replace.

Problem resolved.

Valve has failed.

Replace.

Clean sensor with

a scouring pad.

No

Add 1/8 cup

baking soda to

water and stir.

Is AutoFill

functioning

properly?

No

Yes

Yes

Is AutoFill

functioning

properly?

Substitute a

controller known to

be working for

suspect controller.

No

Yes

No

Is AutoFill

functioning

properly?

Yes

Probable cause is

loose/broken wiring

or damaged sensor.

No

Problem resolved.

Yes

Computer has

failed. Replace.

Advertising
This manual is related to the following products:

8C, 8BC