FUJITSU M3093DG User Manual
Page 81

Sense
key
Additional
sense code
Additional
sense code
qualifier
Description
0
00
00
No> sense
2
00
00
Not ready
3
80
01
Jam
3
80
02
ADF cover open
3
80
03
Document chuter empty of paper
3
80
04
Detects job separation sheet
(See Appendix A.5)
4
80
01
Blown fuse for FB motor
4
80
03
Blown lamp fuse
4
80
04
Blown fuse for ADF motor
4
80
05
Mechanical alarm
4
80
06
Optical alarm
4
44
00
Abnormal internal target
4
47
00
SCSI parity error
5
20
00
Invalid command
5
24
00
Invalid field in CDB
5
25
00
Unsupported logical unit
5
26
00
Invalid field in parameter list
5
2C
2C
02
00
Wrong window combination
(M3096GX/M3093GX)
Command sequence error
(M3093DG)
6
00
00
UNIT ATTENTION
B
43
00
Message error
B
80
01
Image transfer error
l.
Sense>key specific bytes: Bytes F to 11
This field is reserved on this scanner.
(X©00000000π must not be expected.)
4 $ 49