OptiOnal gas line installatiOn

Continued

CAUTION: All gas piping

and connections must be tested

for leaks after the installation

is completed. After ensuring

that the gas valve is on, apply

soap and water solution to all

connections and joints. Bubbles

forming show a leak. Correct

all leaks at once. DO NOT USE

AN OPEN FLAME FOR LEAK

TESTING AND DO NOT OPER-

ATE ANY APPLIANCE IF A LEAK

IS DETECTED. LEAK TESTING

SHOULD BE DONE BY A QUALI-

FIED SERVICE PERSON.

Note: A FMI PRODUCTS, LLC hood must be

installed when using an unvented gas log set

(see Accessories on page 16).

Seal

Opening

with

Refractory

Cement

Outside of

Fireplace

Gas

Line

Conduit

Repack

Insulation

Incoming

1/2" Black

Iron Pipe

Side

Firebrick

Finished

Side

Provide Enough Threaded

End for Fitting Connection

Figure 20 - Gas Line Installation

WARNING: Do not operate an

unvented gas log set in this fire-

place with the chimney removed.

If you install a decorative gas appliance

(vented gas log), the decorative gas appliance

must comply with the Standard for Decorative

Gas Appliance for Installation in Solid Fuel

Burning Fireplaces, ANS Z21.60, Z21.84 or

RG 2-72 and shall also be installed in accor-

dance with the National Fuel Gas Code, ANSI

7223NFPA 54 latest edition.

WARNING: To avoid the risk of

damaging the fireplace materials

and increasing the risk of spread-

ing a fire, do not use the fireplace

to cook or warm food.

WARNING: If the fireplace

has been used for wood burning,

the firebox and chimney must be

cleaned of soot, creosote and

ashes be a qualified chimney

cleaner. Creosote will ignite if

heavily heated.

WARNING: When using a

decorative vented gas log, the

damper must be removed or per-

manently locked in the fully open

position and the glass doors must

be in the fully open position.

Doors Fully Closed

Fireplace Front

Doors

Fully Opened

Fireplace Front

OpeRatiOn and Maintenance guidelines

Figure 21 - Glass Doors

GLASS DOORS

Glass doors are optional with the fireplace.

When the fireplace is in operation, doors

must be fully opened or fully closed position

only or a fire hazard may be created (see

Figure 21).
A fireplace equipped with glass doors oper-

ates mush differently than a fireplace with an

open front. A fireplace with glass doors has a

limited amount of air for combustion. Exces-

sive heat within the fireplace can result if too

large a fire is built or if the combustion air gate

is not completely open.