Venting installation – FMI (V)S36 User Manual

Page 6

Advertising
background image

www.fmiproducts.com

111026-01G

6

Figure 6 - Lineal Gain

Hemmed

End

8" Stainless

Inner Pipe

12

3

/

8

" Galvanized

Outer Pipe

ASSEMBLY AND INSTALLATION OF

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists

of a galvanized outer pipe, a stainless steel

inner flue pipe and a wire spacer. The pipe

sections must be assembled independently

as the chimney is installed.

Venting installatiOn

OPTIONAL OUTSIDE AIR KIT

(MODEL AK4/AK4F)

The installation of an outside air kit should be

performed during the rough framing of the fire-

place due to the nature of it's location. Outside

combustion air is accessed through a vented

crawl space (AK4F) or through a sidewall (AK4).

See Figure 22 on page 13 for instruction of

operating air kit.

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.

The maximum height for the

air vent can not exceed 3 feet

below the flue gas outlet of the

termination.

Figure 5 - Outside Air Kit

Secure to Collars with Metal Tape, Screws

or Straps (Min. of 1/4" x 20" in size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

Vent Hood

Required for

Wall Installation

Air Inlet

Eyebrow

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

CHIMNEY PIPE

The FMI PRODUCTS, LLC chimney system

consists of 12", 18", 24", 36" and 48" snap-

lock, double-wall pipe segments, planned

for maximum adaptability to individual site

requirements. Actual lengths gained after fit-

ting overlaps must be taken into consideration

(lineal gain) and are given in the lineal gain

chart (see Figure 6). Lineal gain is the actual

measurable length of a part after two or more

parts are connected. For Canada, use chimney

parts designated "HT".

WARNING: The opening in

collar around chimney at top of

fireplace must not be obstruct-

ed. Never use blown insulation

to fill chimney enclosure.

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

36"

Fireplace

40"

12-8DM

12-8HT

Pipe Section

10

5

/

8

"

18-8DM

18-8HT

Pipe Section

16

5

/

8

"

24-8DM

24-8HT

Pipe Section

23

5

/

8

"

36-8DM

36-8HT

Pipe Section

34

5

/

8

"

48-8DM

48-8HT

Pipe Section

46

5

/

8

"

RT-8DM Round Termination

6

7

/

8

"*

RTL-8DM Round Termination

7

3

/

4

"*

RTT-8DM Round Termination

with Slip Section

6

7

/

8

" to

23

1

/

8

"*

RTTL-8DM Round Termination

with Slip Section

8

1

/

2

" to

21

1

/

2

"*

ET-8DM

Square Chase-Top

12"*

ETO-8DM Square Chase-Top

with Mesh

12"*

ETL-8DM Square Chase-Top

with Slip Section

7" to 15"*

ETLO-8DM

Square Chase-Top

with Mesh & Slip

Section

12" to

25

1

/

2

"*

* The lineal gain for the terminations is mea-

sured to the flue gas outlet height.

Advertising