Venting installation, Continued, Using elbow offsets (30e-8dm) – FMI (V)S36 User Manual

Page 7

Advertising
background image

www.fmiproducts.com

111026-01G

7

Venting installatiOn

Continued

When connecting chimney directly to the fireplace,

the inner flue pipe section must be installed first

with the lanced side up. The outer pipe section

can then be installed over the flue pipe section with

the hemmed end up. Press down on each pipe

section until the lances securely engage the hem

on the fireplace starter. The wire will assure the

proper spacing between the inner and outer pipe

sections. Continue to assemble chimney sections

as outlined, making sure that both the inner and

outer pipe sections are locked together. When

installing double wall snap-lock chimney together,

it is important to assure the joint between the chim-

ney sections is locked. Check by pulling chimney

upward after locking. The chimney will not come

apart if properly locked. It is not necessary to add

screws to keep the chimney together (exception -

see Figure 9, page 8).

USING ELBOW OFFSETS (30E-8DM)

1. To achieve desired offset, you may install

combinations of 12", 18", 24", 36" and 48"

length of double wall pipe (see offset chart

and Figure 7).

2. Chimney weight above offset rests on

return elbow. Straps must be securely

nailed to rafters or joists (see Figure 8,

details A and B on page 8).

3. Maximum length of pipe between supports

(return elbow or 12S-8DM) is 6' of angle

run. Maximum of two 6' angle run sections

per chimney system (see Figure 7).

4. All pipe connections between offset and

return must be secured with two screws

on outer pipe only (see Figure 9, page 8).

Do not penetrate inner stainless.

OFFSET RISE

CHIMNEY LENGTH

A

B

48" 36" 24" 18" 12"

4

3

/

8

"

16

3

/

8

"

ELBOW SET ONLY

9

3

/

4

"

25

1

/

2

"

1

12

3

/

4

" 30

3

/

4

"

1

15"

34

3

/

4

"

1

18"

40"

1

1

21

1

/

4

" 46

1

/

4

"

1

23

3

/

4

" 49

1

/

4

"

1

1

27

3

/

4

" 56

3

/

4

"

1

30"

60

3

/

4

"

1

1

33"

66"

1

1

36"

71"

1

1

38

1

/

4

"

75"

2

41

1

/

4

" 80

1

/

4

"

1

1

1

45"

86

3

/

4

"

2

46

3

/

4

" 89

1

/

2

"

1

1

1

51"

97"

1

1

53

1

/

4

"

101"

2

1

56

1

/

4

" 106

1

/

4

" 2

59

1

/

4

" 111

1

/

2

" 1

1

1

61

3

/

4

" 115

1

/

2

" 2

1

64

3

/

4

" 120

3

/

4

" 2

1

68

1

/

4

"

127"

1

2

70"

130"

2

1

1

74

1

/

4

" 137

1

/

2

" 1

2

1

76

3

/

4

" 141

1

/

2

" 1

2

1

79

3

/

4

" 146

3

/

4

"

4

OFFSET CHART (22-50 FT. SYSTEM HEIGHT)

Figure 7 - Typical Offset Terminations

Return

Elbow

Offset

Elbow

Return

Elbow

Offset

Elbow

6' Max.

6' Max.

6' Max.

6' Max.

6' Max.

6' Max.

Return

Elbow

Offset

Elbow

Offset

Elbow

Return

Elbow

A

B

C

Offset

Elbow

Ceiling

Support Pipe

12S-8DM

Return

Elbow

Advertising