3 power up – Frymaster HCP User Manual

Page 7

Advertising
background image

HCP

3-1

3 Power Up


ALL ELECTRICALLY OPERATED APPLIANCES MUST BE ELECTRICALLY

GROUNDED IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF

LOCAL CODES, WITH NATIONAL ELECTRIC CODE, ANSI/NFPA NO. 70-1990.


A. Power Requirements:

• Voltage – 208/240 VAC

• 2620 Watts @ 208V – 3420 Watts @ 240V

• Frequency – 50/60 Hertz

• Single Phase

• 20 amp Service


THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG GROUNDING PLUG FOR

YOUR PROTECTION AGAINST SHOCK HAZARD AND MUST BE PLUGGED INTO A

PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE

THE GROUNDING PRONG FROM THIS PLUG.



B. Plug the HCP into the power source.

C. Place the power switch in the ON position. All control displays will illuminate green

approximately 2 seconds after the power switch is activated.


D. Monitor the temperature of the slots. The time it takes the slot(s) to heat from ambient (room)

temperature to a 155

°F (68°C) setpoint should be approximately 15 minutes. It should take

approximately 25 minutes to reach a 200

°F (93°C) setpoint. If setpoint is not consistently

achieved within these limits, call your local Factory Authorized Service Center for repair.


Advertising