Command Specifications

3 -

100

C141-E167

Page parameter length

This field shows the byte length of the page parameter after byte 4.

Page parameter

Data which show the execution results of the operation specified by the SEND DIAGNOSTIC
command are reported in this field.

(1)

Page code list

This response data reports the “Page code” list of the parameter page supported by the IDD in the
SEND DIAGNOSTIC command and the RECEIVE DIAGNOSTIC RESULTS command after byte
4. The format and contents of this response data are shown in Figure 3.22.

Bit
Byte

7

6

5

4

3

2

1

0

0

X ‘00’ (Page Code)

1

0

0

0

0

0

0

0

0

2

X ‘00’ (Page Parameter Length)

3

X ‘02’ (Page Parameter Length)

4

X ‘00’ (Page Code List)

5

X ‘40’ (Logical/Physical Address Conversion)

Figure 3.22 RECEIVE DIAGNOSTIC RESULTS response data: page code list

(2)

Logical/physical address conversion

This response data reports the execution results of address conversion specified in the
“Logical/Physical Address Conversion” parameter in the SEND DIAGNOSTIC command in bytes
after byte 4. The format and contents of this response data are shown in Figure 3.23.