Parameter Data Formats

4 - 20

C141-E167

Bit
Byte

7

6

5

4

3

2

1

0

0

0

0

0

0

0

1

1

1

1

X‘0A’ (Page Length)

2

(Reserved)

EER

PER

DTE

DCR

Default

0

0

0

0

1

0

0

0

Variable

0

0

0

0

1

1

1

1

3

Number of retries during VERIFY.

Default

X‘3F’

Variable

X‘FF’

4

Correctable Bit Length

Default

X‘E9’ (=233 bits)

Variable

X‘00’

5-9

X‘0000000000’ (Reserved)

10-11

Recovery Time Limit

Default

X‘7530’

Variable

X‘FFFF’

Figure 4.5

MODE SELECT parameters: verify error recovery parameters

The error recovery parameters divided in this page descriptor are applicable for the following
commands.

•

VERIFY

•

WRITE AND VERIFY (verify operation)

Note:

If selecting the SCSI-1/CCS mode in the CHANGE DEFINITION command specification, use
Page code = 1 (Read/Write Error Recovery Parameters) instead of this parameter.

a.

Error recovery flags

•

EER (enable early recovery)

•

PER (post error)

•

DTE (disable transfer on error)

•

DCR (disable correction)

The definitions and functions of these control flags are the same as for the read/write error
recovery parameters. See item (1) concerning the details.

(See the
Note.)