Figure 2 - Typical Two-Sided Fireplace

Installation

INTRODUCTION

Models (V)GL36PN/P and (V)GL36PNE/P are

decorative gas appliances that use a millivolt

gas control and piezo pilot or an electronic gas

control valve with an electronic ignition system

respectively. These systems require a 6", B-type

venting system for operation.
The 6" B-type vent is not supplied by FMI PROD-

UCTS, LLC. For installation guidelines, check

your B-vent instructions.

WARNING: This gas appli-

ance must not be connected to

a chimney flue servicing a solid

fuel burning appliance.

Models (V)GL36PN and (V)GL36PNE are smooth

face units for natural gas only. The (V)GL36PNP

and (V)GL36PNEP are smooth face units for

propane/LP gas only. To determine which type of

gas your unit is approved and tested for, check the

rating plate on the lift-out plate located inside the

firebox under the access panel.

BEFORE YOU BEGIN

Before beginning the installation of your appli-

ance, read these instructions through completely.
This appliance and its approved components are

safe when installed according to this installation

manual and are operated as recommended by

FMI PRODUCTS, LLC. Unless you use FMI

PRODUCTS, LLC approved components tested

for this appliance,

YOU MAY CAUSE A FIRE

HAZARD!

The FMI PRODUCTS, LLC warranty will be voided

by and FMI PRODUCTS, LLC disclaims any respon-

sibility for the following actions :
A) Modification of the appliance or any of the

components manufactured by FMI PROD-

UCTS, LLC unless otherwise permitted by

FMI PRODUCTS, LLC.

B) Use of any component part not approved by

FMI PRODUCTS, LLC in combination with

this appliance.

C) Installation and/or operation in a manner other

than instructed in this manual.

D) The burning of anything other than the type of

gas approved for use in this gas appliance.

This appliance, when installed, must be electrically

grounded in accordance with local codes or, in the

absence of local codes, with the National Electrical

Code, ANSI/NFPA 70..
The installation must conform with local codes or, in

the absence of local codes, with the current National

Fuel Gas Code, ANSI Z223.1/NFPA 54.
This appliance complies with ANSI Z21.50 as a

Vented Gas Appliance and is listed and tested by

the PFS Corporation.

WARNING: Installation of

this appliance should be done by

a qualified service person well

trained in the installation of such

appliances. You will also need a

building permit from your local

Building and Safety Commissioner

before installing this appliance;

otherwise your insurance compa-

ny may not cover this appliance.

NOTICE: This appliance is not

intended to be used as a primary

source of heat.

SELECTING LOCATION

To determine the safest and most efficient location

for your appliance, you must take into consider-

ation the following guidelines:
1. The location must allow for proper clearances

(see Clearances, page 6). Note: This decora-

tive appliance is not designed for outdoor

installation.

2. The location should be in a place where drafts,

air conditioning ducts, windows or doors will

not affect fireplace heat output.

3. A location that avoids the cutting of joists

or roof rafters will make installation easier.

Figure 2 shows a typical three-sided fireplace

installation.

IMPORTANT: Side openings must be located at

least 3 feet from facing wall or combustible mate-

rial. End opening must be located at least 1 foot

from facing wall or combustible material.

Existing

Side

Wall

4" From Opening to

Perpendicular Wall