FRAMING

Construct framing using dimensions shown if Figures

6, 7 and 8. (Use the figure applicable to your applica-

tion.) Figure 6 shows the framing dimensions prior

to having the appliance in place. If installing on a

platform, platform must be solid, flat and fully sup-

ported (see Figure 7). Once the unit has been fitted,

bring studs in against nailing flanges located on the

side of the appliance making sure a 1" clearance is

maintained as shown in Figure 8.
If the fireplace is to be installed directly on carpeting,

tile (other than ceramic) or any combustible mate-

rial other than wood flooring the fireplace must be

installed upon a metal or wood panel extending the

full width and depth of the fireplace.

Figure 6 - Framing Dimensions Prior to

Placing Appliance

Figure 8 - Securing Appliance with

Nailing Flanges

52

3

/

4

"

Min.

40

3

/

8

"

22

3

/

4

"

VENT PIPE INSTALLATION

A 6", B-1 type gas vent pipe is a double-wall, vent-

ing system (not supplied) which must be installed

during rough framing of the appliance. Any B-1

type gas vent system may be used for proper vent-

ing as long as the vent system is installed per the

vent manufacturer’s recommendations.
FMI PRODUCTS, LLC supplies this appliance

with a tapered starter pipe for a snug fit. Slide B-1

type vent pipe over this starter pipe until vent pipe

is fully seated. Secure this first section of B-vent

pipe by strapping the connector around the vent

pipe and then tightening the strap with any 1/8"

nut and bolt (see Figure 9). Note: Visually inspect

for proper vent connection by looking inside top

of appliance. If connection does not appear to be

correct, contact your local service technician.

Figure 9 - Installing B-Vent Pipe

Nailing Flanges

1" Min. to Combustibles

Prepared Framing

Nails or Screws

B-1 Type

Vent (Not

Supplied)

Strap

(Fasten with

#6 Screw or

Bolt)

52

3

/

4

"

Min.

22

3

/

4

"

*

Figure 7 - Framing Dimensions Prior to

Placing Appliance Using a Platform

*As required by design as

long as ceiling clearance is

maintained