Fireplace installation, Continued optional outside air kit (model ak4), Millivolt models (gl36pn/pnp and vgl36pn/pnp) – FMI (V)GL36PNE User Manual

Page 8: Electronic models (gl36pne/pnep and vgl36pne/pnep)

Advertising
background image

www.fmiproducts.com

55175G

8

FIREPLACE

INSTALLATION

Continued

OPTIONAL OUTSIDE AIR KIT

(MODEL AK4)

The installation of an outside air kit should be

completed during the rough framing of the fire-

place due to the nature of it's location. Outside

combustion air is accessed through a vented

crawl space.

CAUTION: Air inlet ducts

must not be terminated in an

attic space.

Avoid installing outside air eyebrow in areas where

inlet opening may be blocked by snow, bushes or

other obstacles (see Figure 10).
The maximum height for the air inlet termination

cannot exceed 3 feet below the B-vent termination

exhaust height.

Figure 10 - Outside Air Kit

Secure to Collars with Duct Tape or

Screws

Air Inlet

Location

Must Allow

For Bushes

or Snow

Vent Hood

Required for

Wall Installation

Air Inlet

Eyebrow

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

MILLIVOLT MODELS (GL36PN/PNP

AND VGL36PN/PNP)

The installation of a wall switch in this millivolt

control appliance allows you to activate the gas

control valve without the use of normal current.

CAUTION: Do not connect

this millivolt system wall switch

to a regular 120v power source!

Gas valve will be damaged be-

yond repair.

Wall Switch Installation

1. Remove the J-box cover plate from side of

appliance’s outer surround.

2. Using the 18 ga. millivolt wire and wall switch

(both supplied), connect wiring per wiring

diagram (see Figure 11). For more detail, see

Wiring Diagrams on page 16.

Note: If any of the original 10 feet supplied wire

must be replaced, use Thermostat Millivolt Wire

18 AWG Type CL2-105 C or equivalent only.
IMPORTANT: Do not hook up to standard 120

VAC household wiring.

Figure 11 - Wall Switch Installation

O

F

P

IL

O

T

ON

F

T

O

I

P L

7

TP

T

H

TP

TH

Wall Switch

(Supplied)

Back View

To Thermopile

Route Millivolt Wires

(Supplied) Through

Electrical Conduit Bushing

ELECTRONIC MODELS

(GL36PNE/PNEP AND

VGL36PNE/PNEP)

This appliance must be properly wired to standard

120v household current through the FMI PROD-

UCTS, LLC provided wall switch before its remote

control unit can be used to activate the automatic

pilot ignition (turn fireplace flames ON).
Wall Switch Installation

1. Remove the J-box cover plate from side of

appliance’s outer surround.

2. Using the 18 ga. wires coming through strain

relief grommet on side of appliance’s outer

wall to standard household 120 VAC current

through the wall switch provided, as shown in

Figure 12, page 9. For more detail, see Wiring

Diagrams, page 16.

Note: If any of the original 10 feet supplied wire

must be replaced, use 20 AWG electrical wire or

equivalent only.